Tysk tillverkade  Vattenburna Pannor från Tyska WOLF, Supersnygg design förenad med  högsta  Kvalité ,8 olika modeller finns att tillgå,med/utan tappvatten tank, 5 års Fabriksgaranti på rostfria förbränningskammare 6års Fabriksgaranti på pannan,levereras kompletta med Kroll Alloljebrännare i 8 olika effekter, från Villa Panna -200 KW

diagram_vattenburna_sid_2

Kroll Boiler Figure KWOB... 20 20 T 35 35 T 55 55 T
Output range kW 17-20 17-20 25-32 25-32 50-63 50-63
Output range in BTU's in 000's BTU's 58-68 58-68 85-109 85-109 170-290 170-290
Tank capacity Ltr. 155 – 200 200
Continous output of tank ltr/h 490 – 780 1225
Output factor of tank NL 2,8 – 4,8 5
Boiler water content ltr. 51 51 68 68 105 105
Boiler gas content ltr. 36 36 61 61 130 130
Hot water resistance (at ∆t=20K) mbar 6 6 10 10 22 22
max. permissible boiler pressure bar 3 3 3 3 3 3
max. permissible storage tank pressure bar 10 – 10 10
Relative boiler standby loss % 1,6 1,6 1,1 1,1 0,7 0,7
Required boiler draught Pa 3 3 5 5 8 8
Flue-gas temperature* °C 160-180 160-180 180-200 180-200 165-180 165-180
Flue-gas mass flow* kg/h 29-34 29-34 42-54 42-54 85-107 85-107
Weight boiler kg 135 135 169 169 258 258
Weight of storage tank kg 66 – 83 83
Diameter of flue-gas pipe mm 129 129 149 149 179 179
Boiler flow/ boiler return G 1 1/2” 1 1/2” 1 1/2” 1 1/2” 1 1/2” 1 1/2”
Filling Emptying R 1” 1” 1” 1” 1 1/4” 1 1/4”
Vent safety feed line R 1” 1” 1” 1” 1 1/4” 1 1/4”
Cold water feed line/ hot water connection R 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
Storage tank circulation pipe R 3/4” – 3/4” 3/4”
Height of boiler A mm 670 670 670 670 845 845
Width of boiler / storage tank B mm 660 660 660 660 760 760
Length of boiler C mm 756 756 876 876 1056 1056
Length of storage tank D mm 987 – 1262 1262
Length of burner E mm 290 290 290 290 290 290
Overall height with control unit F1 mm 1115 1115 1115 1115 1635 1635
Overall height with control unit F2 mm 1460 1460 1460 1460 1635 1635
Flue connection G1 mm 607 607 607 607 657 657
Flue connection G2 mm 952 – 952 1002
Heating connections H mm 260 260 260 260 300 300
Heating connections J mm 326 326 390 390 484 484
Electrical connections 230 V/50 Hz/10 A
* Value for lower/upper boiler output in recommended output range, related to CO2 content of 13% and mean boiler water temperature of 60°C. Stack dimensions must be calculated in accordance with DIN 4705.

diagram_vattenburna_sid_3adiagram_vattenburna_sid_3b

Kroll Boiler Figure KWOB 85 KWOB 100 KWOB 150 KWOB 200
Output range kW 70-85 85-99 110-160 160-200
Output Range in BTU's - in 000's Btu's 238-290 290-338 375-511 546-682
Height/height without casing A mm 1180/1155 1180/1155 1180/1155 1346/1320
Width/ width without casing B mm 794/600 794/600 794/600 974/780
Length C mm 1410 1410 1760 1948
Total height with control system D mm 1335 1335 1335 1500
Length of burner E mm 290 290 440 440
Filling draining F mm 203 203 203 172
Flue- gas pipe connection G mm 922 922 922 1048
Heating return H mm 324 324 324 367
Heating flow J mm 724 724 1074 1117
Expansion flow K mm 874 874 1224 1407
Flue- gas pipe diameter mm 178 178 195 195
Foundation mm 1500 x 950 1500 x 950 2000 x 1000** 2000 x 1000**
Filling, draining, expansion return R 1 1/2" 1 1/2" 1 1/2" 1 1/2"
Heating return Flange DN 65 65 65 80
Heating flow Flange DN 65 65 65 80
Expansion flow, vent (ext. thread) R 1 1/4" 1 1/4" 1 1/4" 1 1/2"
Water capacity of boiler Ltr. 216 213 288 508
Gas capacity of boiler Ltr. 140 143 206 333
Heating surface area m2 3,5 3,8 5,2 8
Flue- gas resistance1 mbar 0,3 0,4 0,8 1,1
Heating water resistance (at ∆t=20K)1 mbar 1,2 1,7 3,5 4,5
Max. boiler overpressure (gauge) bar 4 4 4 4
Max. permissible temperature2 °C 120 120 120 120
Relative stand-by loss % 0,7 0,7 0,6 0,5
Flue- gas temperature1 °C 145-165 145-165 145-165 145-165
Flue- gas temperature 1st stage °C 120 120 120 120
Flue- gas mass flow1 (Flue oil EL CO2 =9.5%) kg/h 127-142 142-168 184-235 269-319
Flue- gas mass flow1 (Natural Gas E CO2 =9.0%) kg/h 125-151 151-178 196-249 285-338
Flue- gas mass flow1 (Natural Gas LL CO2 =9.0%) kg/h 129-157 157-185 203-259 269-351
Flue- gas mass flow1 (LPG CO2 =11%) kg/h 120-146 146-172 189-240 274-326
Weight Boiler kg 406 413 524 730
Electricity supply 230 V/50 Hz/10 A
1 Figures for upper/lower boiler output in recommended range with a CO2 content of 13% and a main boiler water temperature of 60 °C
2 Overheat safety cutout convertible: 120 °C/ 110 °C/ 100 °C
The dimension of their chimney have to be selected in accordance with DIN 4705. If the flue-gas temperature is below 160°C the boilers have to be connected wither to highly insulated chimneys (heat transfer resistance group in accordance with DIN 18160 part1) or any other
approved humidity resistant flue gas systems.